Machine fails to disconnect the Tool Carriage from the Head Carriage. Limit Position Initialize, head carriage not locked Loose Connection in scan axis. Disorder of Cap Motor Limit Sensor does not work correctly or is broken.

1) Check the mechanical backlash in scan motor, or drive wire.
2) Lock Position Adjustment
3) Limit Position and Cut Down Position Initialize